The TF03 is an industrial-grade high-speed measurement LiDAR with a range of up to 180 meters. It integrates compensation algorithms for outdoor strong light, rain, snow, and fog, ensuring normal operation in these challenging environments. Multiple measurement modes and configurable parameters are available to meet diverse ranging requirements.

Technical Specifications

Performance Parameters

ModelTF03-100TF03-180
Detection range①100 m @ 90% ref.40 m @ 10% ref.180 m @ 90% ref.70 m @ 10% ref.
Blind zone≤ 0.1 m
Accuracy①± 10 cm (< 10 m), 1% (≥ 10 m)
Repeatability①< 3 cm @ 1σ
Distance resolution1 cm
Default frame rateUp to 9,800 Hz (1 ~ 9,800 Hz configurable, default 100 Hz)
Ambient light resistance100 KLux

Optical Parameters

ParameterValue
Light sourceEEL
Central wavelength905 nm
FoV②< 0.5°
Eye safetyClass 1 (IEC 60825-1:2014; EN 60825-1:2014+A11:2021)

Mechanical and Electrical Parameters

ParameterValue
Average power consumption③≤ 800 mW
Peak current③< 480mA @ 12V
Power supplyDC 5V ~ 24V
Logical voltage3.3 V TTL
ConnectorMolex standard 7pin terminal, model MH1.25-7P-W/B
Operating temperature- 25 ℃ ~ + 60 ℃
Storage temperature- 40 ℃ ~ + 85 ℃
Protection levelIP67
Typ. Dimensions②44.0 mm x 43.0 mm x 32.0 mm
Cable length②70 cm
Typ. Weight②86 ±3g (excluding cables)

Communication Protocol

UART / CAN (Can be switched by command), RS232, RS485

Please note that the above communication interfaces belong to three independent hardware models. Please choose the corresponding product model according to your needs.

Dimensions (Unit: mm)

Source figure, page 2

TF03

Notes:

1. When all the light spots fall on the target object, the accuracy, distance resolution, and repeatability are measured under the conditions of a diffuse reflection whiteboard (90% reflectivity) at 25 ℃ indoors;

2. The weight and size are typical values for reference only. For detailed tolerance parameters, please consult the technical personnel of Benewake;

3. Measured at a temperature of 25 ℃, 100 Hz;

Product inquiry