跳到主要内容

ArduPilot · configuration

TFmini-S 接入 ArduPilot I²C / CAN / UART / TTL:接入与配置指南

TFmini-S 接入 ArduPilot 的准备、连接、配置与代码要点。原始文件可在资料下载区获取。涉及接口:I²C、CAN、UART / TTL。

接口
I²C, CAN, UART / TTL
整理日期
2026-08-31
资料说明
资料版本日期:2026-08-31。

适用范围

TFmini-S · ArduPilot · I²C、CAN、UART / TTL

原始英文技术说明

Application of TFmini-S IIC in PixHawk (ArduPilot Firmware)

TFmini-S can be used with PixHawk for the purpose of obstacle avoidance.

1. TFmini-S Settings:

Note: Frame rate should be set to 250Hz, see the details in chapter 7.4 “frame rate” and changing the communication interface.

The default communication of TFmini-S is TTL, IIC and TTL uses the same cable, so please set
TFmini-S to IIC communication first, see detail commands in product manual.

We take two TFmini-S as an example in this passage and set the address 0x10 and 0x11 separately.

2. PixHawk Connection:

See the connection details in PixHawk manual and TFmini-S manual, we take example for connecting

PixHawk flight controller:

Figure 1: Schematic Diagram of Connecting TFmini-S to I2C Interface of PixHawk

Note:

1. Default cable sequence of TFmini-S and PixHawk are different, please change it accordingly

(SDA and SCL wires need to be interchanged). Look at the pinout of controller, pin configurations are starting from left to right:

Page2

2. IIC connector should be purchased by user

3. If TFmini-S faces down, please take care the distance between lens and ground should be larger

than TFmini-S’s blind zone (10cm)

4. If more TFmini-S need to be connected (10 LiDARs can be connected), the method is same.

5. Power source should meet the product manual demands:5V±0.5V, larger than 140mA*number of
TFmini-S

3. Parameters settings:

Common settings:

AVOID_ENABLE= 2 [if 3 = UseFence and UseProximitySensor doesn’t work in IIC then choose 2 =
UseProximitySensor]
AVOID_MARGIN=4
PRX_TYPE=4

Settings for first TFmini-S:

RNGFND1_ADDR=16 [Address of #1 TFmini-S in decimal]
RNGFND1_GNDCLEAR=15 [Unit: cm, depending upon mounting height of the module and should be
larger LiDAR than non-detection zone]
RNGFND1_MAX_CM=400 [It could be changed according to real demands but should be smaller than
effective measure range of LiDAR, unit is cm]
RNGFND1_MIN_CM=30 [It could be changed according to real demands and should be larger than
LiDAR non-detection zone, unit is cm]
RNGFND1_ORIENT=0 [#1 TFmini-S real orientation]
RNGFND1_TYPE = 25 [TFmini-S IIC same as TFmini-Plus IIC]

Page3

Settings for second TFmini-S:

RNGFND2_ADDR=17 [Address of #2 TFmini-S in decimal]
RNGFND2_GNDCLEAR=15
RNGFND2_MAX_CM=400
RNGFND2_MIN_CM=30
RNGFND2_ORIENT=25 [#2 TFmini-S real orientation]
RNGFND2_TYPE=25 [TFmini-S IIC same as TFmini-Plus IIC]

Upon setting of these parameters, click [Write Params] on the right of the software to finish.

If the error message “Bad LiDAR Health” appears, please check if the connection is correct and the power supply is normal.

How to see the target distance from the LiDAR: press Ctrl+F button in keyboard, the following window will pop out:

Page4

Click button Proximity, the following window will appear:

The number in green color means the distance from LiDAR in obstacle avoidance mode(the number only refresh when this window opens, closes, zooms in or zooms out, it doesn’t mean the real time distance from LiDAR and will not be influenced in Mission Planner version under v1.3.48, the problem could be solved by updating Mission Planner

Page5

使用说明

按原始资料可读取的技术内容编排;具体的产品硬件版本、飞控/软件版本和现场安全边界仍应以原始资料及目标平台当前文档为准。

资料与下载

产品咨询

咨询产品方案

留下需求,我们会尽快与您联系。

产品咨询

提交成功