跳到主要内容

技术资料

tf350 用户手册

TF350 - UART / CAN

Source figure, page 1

TF350 - UART / CAN

Source figure, page 1

Benewake (Beijing) Co., Ltd

PREFACE

Dear users: Thank you for choosing Benewake products. For the purpose of offering better operation experience to you, we hereby write this manual for an easier and simpler operation of our product, hoping to better solve the common problems you may meet. This user manual contains the relevant information on product introduction, usage and maintenance of Long-range single-point LiDAR: TF350-UART / CAN, covers the product operation introduction and common problem solutions. Please read this manual carefully before using the product. Remember the precautions to avoid hazards, and please follow the described steps in the manual when using it.

If you have any problems in the process of usage, you are welcome to contact Benewake at any time for help.

Contact details Official website: https://ai.benewake.com/zh/products/tf350/ TEL:+86-10-57456983 Technical questions,please contact: support@benewake.com Consult sale information or request brochure,please contact: bw@benewake.com

Headquarters Address Benewake (Beijing) Co., Ltd. 3rd Floor, Haiguo Jiaye Sci-Tech Park, Haidian District, Beijing, China

Copyright Statement This User Manual is copyright © Benewake. Please do not modify, delete or translate the description of this manual contents without the official written permission from Benewake.

Disclaimer As our products are constantly improving and updating, the specifications of Long- range single-point LiDAR: TF350-UART / CAN. are subject to change. Please refer to the official website for latest version

CONTENTS

1 OVERVIEW ......................................................................................................................... 1 1.1 Failure scenarios ........................................................................................................ 1 1.2 Symbols and document conventions ...........................................................................2 2 PRODUCT DESCRIPTION ...................................................................................................... 3 2.1 Appearance overview .................................................................................................3 2.2 Dimensional drawing ................................................................................................. 3 2.3 Measuring principle ....................................................................................................4 2.4 Technical specification ............................................................................................... 4 2.5 FoV ............................................................................................................................ 6 3 ELECTRICAL INSTALLATION ................................................................................................. 8 3.1 Pin and wire color assignment ....................................................................................8 3.2 Wire cross-sections .....................................................................................................8 3.3 Wiring UART interface .................................................................................................9 3.4 Wiring CAN interface .................................................................................................. 9 3.5 CAN bus ................................................................................................................... 10 4 PROTOCOLS ......................................................................................................................12 4.1 Communication protocol of UART ..............................................................................12 4.2 User protocol: UART ................................................................................................. 12 4.3 Communication protocol of CAN ............................................................................... 13 4.4 User Protocol: CAN ................................................................................................... 14 5 CUSTOM CONFIGURATION .................................................................................................15 5.1 Protocol description ..................................................................................................15 5.2 Common commands .................................................................................................15 5.3 Command editing ..................................................................................................... 17 6 OPTIONAL ACCESSORIES ....................................................................................................19 6.1 Extension cord ..........................................................................................................19 7 QUICK START GUIDE ..........................................................................................................20 7.1 Connection and basic test ......................................................................................... 20 7.2 Troubleshooting guide for initial test ........................................................................ 21 7.3 Working mode ..........................................................................................................21 7.4 Influences of object surfaces on the measurement .................................................... 22 8 TROUBLESHOOTING ...........................................................................................................26 ATTACHMENT 1: Reflectivity of Different Materials ................................................................. 28

Source figure, page 4

OVERVIEW

1 OVERVIEW

The Reference Manual is a complement to the Operating Instructions for TF350. The Operating Instructions for TF350 describes how to set up and configure the interfaces. The Reference Manual contains detailed information about the interfaces including syntax and available functionality. It focuses on TF350 specific topics and does not describe the basic technology behind each interface. The details of the result output formatting and the contents and syntax of the command channels are shared by several interfaces. They are described in an appendix valid for all relevant interfaces.

1.1 Failure scenarios

As a precision optical distance sensor, TF350 ’ s performance is greatly affected by environment. Certain scenarios will even damage TF350. Each of these failure scenarios have been tested in real field tests. Table 1 Failure scenarios of TF350

ParameterValue
ScenarioDescription Scenario Description
Do not cover the laserAvoid moving
window.objects in the
Source figure, page 4
Source figure, page 4

detection field.

Source figure, page 4
Source figure, page 4

Avoid the presence of Avoid heavy smoke, fog and condensation. rain in the detection field.

Source figure, page 4
Source figure, page 4
ParameterValue
Avoid direct exposureAvoid exposure to
to high pressurestrong light source
cleaning.with same

wavelength.

Source figure, page 5

OVERVIEW

Source figure, page 5
Source figure, page 5
ParameterValue
Do not expose toAvoid extreme
corrosive liquids.vibrations.
Do not use inDo not use in
extremely lowextremely high
temperaturetemperature
environments.environments.
Avoid exposure toAvoid direct
sudden and extremeexposure to another
temperature changes.LiDAR with same
Source figure, page 5
Source figure, page 5
Source figure, page 5
Source figure, page 5

wavelength.

1.2 Symbols and document conventions

The following symbols and conventions are used in this document:

WARNING Indicates a situation presenting possible danger, which may lead to death or serious injuries if not prevented.

CAUTION Indicates a situation presenting possible danger, which may lead to moderate or minor injuries if not prevented.

NOTICE Indicates a situation presenting possible danger, which may lead to property damage if not prevented.

NOTE Indicates useful tips and recommendations.

Source figure, page 6

PRODUCT DESCRIPTION

2 PRODUCT DESCRIPTION

2.1 Appearance overview

①

Source figure, page 6

②

③ ④

Figure 1 Module view of TF350

1 6 core cable (70cm), the connector is Molex SD-51021-007 1.25 W/B-7Pin also called MH1.25-7P-W/B. 2 Laser window (Receiving) 3 Laser window (Emitting) 4 3mm diameter hole (6mm deep) for mounting (6x) 2.2 Dimensional drawing

Source figure, page 6

①

② ③

Figure 2 Dimensional drawing of TF350 (① Front;②

Source figure, page 7

PRODUCT DESCRIPTION

2.3 Measuring principle

TF350 is a Pulse Time of Flight (PToF) sensor. TF350 emits a narrow pulse laser, which is

collimated by the transmitting lens, which enters the receiving system after being

reflected by the measured target and is focused on the APD detector by the receiving

lens. The time between the transmitted signal and the received signal is calculated

through the circuit amplification and filtering, and the distance between TF350 and the

measured target can be calculated through the speed of light.

Source figure, page 7

Figure 3 Pulsed time of flight (PToF)

2.4 Technical specification

Table 2 Technical specifications of TF350

ParameterValue
ParametersMinimum Typical Maximum
Range (@90% reflectivity, 0klux)0.2m 350m
Range (@10% reflectivity, 0klux)0.2m 110m

Range (@90% reflectivity, 0.2m 300m

Performance 100klux)

Range (@10% reflectivity, 0.2m 100m

100klux)

Accuracy ±10cm (<10m), 1% ≥10m)

Source figure, page 8

PRODUCT DESCRIPTION

Distance resolution 1cm Frame rate 1Hz 100Hz 1000Hz Repeatability 1σ:

<3cm

Light source LD Central wavelength 905nm Photobiological safety Class1(EN60825) FoV 0.35° Ambient light immunity 100Klux

Environment Operation temperature -25℃ 60℃

Enclosure rating IP67 Supply voltage 5V DC 24V DC Average current ≤150mA @ 5V, ≤80mA @ 12V, ≤

50mA @ 24V

Connections Power consumption ≤1W

Communication interface level LVTTL

(3.3V)

Communication interface RS-485 /

RS-232

Dimension 78mm*67mm*40mm(L*W*H) Housing Aluminum alloy

Others Optical window Infrared optical glass (HWB760)

Storage temperature -40℃ 85℃ Weight 222g ± 3g Cable length 70cm

NOTICE The basic technical specifications, like accuracy and repeatability, are measured with white background board (90% reflectivity) at 0klux condition.

NOTICE Only the frame rate satisfying the following formula is supported.

Frame rate = a × 10 b, a ∈ {1,2,3,4,5,6,7,8,9}, b ∈ {0,1,2,3}

If a value which does not satisfy this formula is set, TF350 will set its frame

Source figure, page 9

PRODUCT DESCRIPTION

rate to 100Hz. The normal frame rate is under 1kHz, but the maximum frame rate can reach as much as 7kHz. Please contact us if you need higher frame rate.

2.5 FoV

The field-of-view, FoV, is the angle covered by the LiDAR sensor. The horizontal FoV of TF350 is about 0.35° and the vertical FoV of TF350 is approx. 0.1°.

Source figure, page 9
Source figure, page 9

Figure 4 FoV of TF350. Horizontal divergence 0.35°, vertical divergence 0.1°

NOTICE 0.35° and the installing error exist, there is divergence between each and 0.1° are theoretic values. Because the manufacturing error TF350’s actual FoV and its theoretic values.

Source figure, page 10

PRODUCT DESCRIPTION

Source figure, page 10
Source figure, page 10

Figure 5 Spot size of TF350 at different ranges

Source figure, page 11

ELECTRICAL INSTALLATION

3 ELECTRICAL INSTALLATION

3.1 Pin and wire color assignment

TF’s cable has six 26 AWG wires. The connector is Molex SD-51021-007 1.25 W/B-7Pin (MH1.25-7P-W/B).

Source figure, page 11

Figure 6 Male connector, Molex SD-51021-007 1.25 W/B-7Pin

Table 3 Pin assignment on 7-pin male connector Pin Color Signal Function 1 Red DC 5~24V Supply Voltage 2 White CAN_L CAN-BUS Low 3 Green CAN_H CAN-BUS High 4 N/A N/A N/A 5 Blue UART RxD UART Receive 6 Brown UART TxD UART Transmit

3.2 Wire cross-sections

CAUTION If you use flexible connecting cables with stranded wire, then you must not use ferrules when connecting the wires to the terminals on TF350.

Wire all connections with copper cables! Use the following wire cross-sections:  supply voltage at least 0.13 mm ² (approx. 26 AWG), if local power supply in the immediate vicinity.  supply voltage at least 0.21 mm ² (approx. 24 AWG) at maximum length of 2m (6.562 ft), if the connection is made to an existing 24 V DC supply.

Source figure, page 12

ELECTRICAL INSTALLATION

 switching outputs minimum 0.13 mm ² (approx. 26 AWG), maximum cable length 2m (6.562 ft) with 0.21 mm² (approx. 24AWG).  data interface minimum 0.21mm² (approx. 24 AWG). 3.3 Wiring UART interface

A screened cable is required for the wiring of the UART interface.  Pay attention to max. cable length as per section Wire cross-sections.

Source figure, page 12

Figure 7 Wiring of the UART interface

NOTICE To connect two devices for UART serial communication, the transmitter ’ s TXD should connect to the receiver ’ s RXD and the receiver ’ s TXD should connect to the transmitter’s RXD.

3.4 Wiring CAN interface

To wire the CAN interface a screened “twisted-pair” cable is required. Pay attention to max. cable length as per section Wire cross-sections.

Source figure, page 12

Figure 8 Wiring of the CAN interface

Source figure, page 13

ELECTRICAL INSTALLATION

3.5 CAN bus

Unlike a traditional network such as USB or Ethernet, CAN does not send large blocks of data point-to-point from one node to another under the supervision of a central bus master. Once CAN basics such as message format, message identifiers, and bit-wise arbitration - a major benefit of the CAN signaling scheme are explained, a CAN bus implementation is examined, typical waveforms presented, and transceiver features examined.

Source figure, page 13

Figure 9 CAN networking of TF350

The High-Speed ISO 11898 Standard specifications are given for a maximum signaling rate of 1 Mbps with a bus length of 40 m with a maximum of 30 nodes. It also recommends a maximum unterminated stub length of 0.3 m. The cable is specified to be a shielded or unshielded twisted-pair with a 120-Ω characteristic impedance (Zo). For CAN bus connection, there are two resistances need to be removed from TF350. See Figure 10 Resistances needed to be removed from board for CAN Bus for the location of Resistance #2 and #3.

Source figure, page 14

ELECTRICAL INSTALLATION

Source figure, page 14

R2

R3

Figure 10 Resistances needed to be removed from board for CAN Bus WARNING Removing resistance R2 and R3 needs to disassemble TF350. To avoid irreversible damage to TF350, please contact our technical support engineers for detailed instructions.

Source figure, page 15

PROTOCOLS

4 PROTOCOLS

The standard version of TF350 supports two communication interfaces, UART and CAN. The default interface is UART. These two interfaces cannot work simultaneously. The communication interface can be switched by certain command. 4.1 Communication protocol of UART

Table 4 Characteristics of UART

ParameterValue
CharacterValue Configurability
Baud rate115200 Configurable
Data bit8 Non-configurable
Stop bit1 Non-configurable
ParityNone Non-configurable

NOTE Baud rate of UART can be set to 9600, 14400, 19200, 38400, 56000, 57600, 115200, 128000, 230400, 256000, 460800, 512000, 750000, 921600, 1000000, 1500000 and 2000000. If other value were set, TF350 will automatically set it to 115200.

4.2 User protocol: UART

A standard data frame consists of 9 bytes of hexadecimal numbers, which contains distance and signal strength.

NOTE Strength value is between 0 and 3500. Threshold of strength is 40, when strength is lower than 40, distance will output maximum value. When strength is between 40 and 1200, distance is more reliable. When detecting a high reflectivity object, signal strength will be over 1500.

Source figure, page 16

PROTOCOLS

Source figure, page 16

Figure 11 Data communication: User protocol frame format of UART

Each data frame consists of 9 bytes hexadecimal data which contains the distance and signal strength.

NOTE Strength value is between 0 and 3500. Threshold of strength is 40, when strength is lower than 40, distance will output maximum value. When strength is between 40 and 1200, distance is more reliable. When detecting a high reflectivity object, signal strength will be over 1500.

4.3 Communication protocol of CAN

The CAN interface supports data transmissions between 10Bit/s and 1Mbit/s. The maximum cable length is 2m (6.562ft). Table 5 Characteristics of CAN

ParameterValue
CharacterValue Configurability
Baud rate1MBit/s Configurable
Receiving ID0x3003 Configurable
Transmitting ID0x03 Configurable
Message framesStandard Frame Configurable

Extended Frame

Source figure, page 17

PROTOCOLS

NOTE Baud rate of CAN can be set to 20000, 33330, 40000, 50000, 66660, 80000, 83330, 100000, 125000, 200000, 250000, 400000, 500000, 666000, 800000 and 1000000. If other value were set, TF350 will automatically set it to 1000000.

4.4 User Protocol: CAN

Source figure, page 17

Figure 12 Data communication: User protocol frame format of CAN

Source figure, page 18

CUSTOM CONFIGURATION

5 CUSTOM CONFIGURATION

5.1 Protocol description

To meet the need of different customers, TF350 released several configuration parameters. These parameters, such as data format, frame rate, could be modified by certain command. All the parameters will be stored in flash after configured successfully and customers don’t need to configure again when restart. Table 6 Description of TF350 command protocol

ParameterValue
Byte DefinitionDescription
Byte 0Header Fixed to 0x5A
Byte 1Len The length of the entire instruction frame (unit:

Byte)

Byte 2 ID Identifies the function of each instruction Byte 3~Byte N-2 Payload Different meanings and lengths in different ID

instruction frames

Byte N-1 Check sum The low 8 bits of the Len-1-byte data

5.2 Common commands

Table 7 List of TF350’s common commands

ParameterValue
DescriptionCommand Response Remark Default setting
firmware Obtain5A 04 01 5F 5A 07 01 VA VB The version /
versionVC SU number VC.B.A
System reset5A 04 02 60 5A 05 02 00 61 / /
Modify frame 5A 06 03 LL HHSame as LL: lower 8 bits 100Hz
rateSU command HH: higher 8 bits
On: 5A 05 07 0167
Output controlcommand Same as / Enabled
Off: 5A 05 07 0066
Source figure, page 19

CUSTOM CONFIGURATION

command Enable Same as triggering 5A 05 07 00 66 command / Disabled mode

ParameterValue
Trigger5A 04 04 62 Data frame Only works in command /
measurementtriggering mode
Change baud 5A 08 06 H1 H2Same as Command See 5.3 115200
rateH3 H4 SU command editing
Restore default settings5A 04 10 6E 5A 05 10 00 6F / /
Save settings5A 04 11 6F 5A 05 11 00 70 / /
Over range 5A 06 4F LL HHUnit: cm
threshold settingSU 5A 05 4F 00 AE LL: lower 8 bits 35000

HH: higher 8 bits

Switch UART: 5A 05 45 01 A5 communication interface CAN: 5A 05 45 5A 05 45 00 A4 / UART

02 A6

ParameterValue
Modify CAN 5A 08 50 H1 H25A 05 50 00 AF ID = (H4<<24) +(H3<<16) 0x03
arbitration IDH3 H4 SU +(H2<< 8) +H1
Modify CAN 5A 08 51 H1 H25A 05 51 00 B0 ID=(H4<<24) +(H3<<16) 0x3003

H3 H4 SU +(H2<< 8) +H1

Modify baud 5A 08 52 H1 H2 rate=(H4<<24) Baud rate of CAN H3 H4 SU 5A 05 52 00 B1 +(H3<<16) 1Mbits/s

+(H2<<8) +H1

Standard frame: 5A 05 5D 00 BC

ParameterValue
Set frame type of CANExtension 5A 05 5D 00 BC / Standard frame
frame: 5A 05 5D01 BD
EnableMD:filter switch
UAVCAN 5A 05 77 MD SU5A 05 77 00 D6 0x00:filter off /

0x01:filter on

Source figure, page 20

CUSTOM CONFIGURATION

5A 06 69 LL HH Unit: cm

Offset setting SU 5A 05 69 00 C8 LL: lower 8 bits 0

HH: higher 8 bits

ParameterValue
Low-power On: 5A 05 83 01E3
consumptioncommand Same as / Off
mode Off: 5A 05 83 00E2

WARNING Do not send the command that is not in the list above.

NOTE Offset configuration can be used for secondary calibration of distance, for example, when distance is 195cm and you want LiDAR outputs 200cm, you can set offset value to 5cm.

5.3 Command editing

This section describes the Command Channel of TF350 which is used to read and set TF350’s working parameters. The command channel is available via all the interfaces. A standard TF350 command consists of frame header, command length, command ID, parameters, and checksum. Follow these steps to generate a command:  Choose the right command ID and confirm its length  Convert parameter from the decimal value to hexadecimal value  Fill the hexadecimal parameter into the command  Calculate the checksum and fill its low 8-bits into the command For example, changing the baud rate to 460800. Firstly, choose the ID of changing frame rate, which is 0x06. Secondly, change 460800 (decimal number) to hexadecimal number, which is 0x00 07 08 00. Thirdly, fill the parameter into the command, like 5A 08 06 00 08 07 00 SUM. Finally calculate the sum of the first 7bytes and take its low 8bits, we will have the complete command, 5A 08 06 00 08 07 00 77.

Source figure, page 21

CUSTOM CONFIGURATION

Header Length ID Hexadecimal parameters Checksum

Fixed: 0x5A Length of the command (Number of bytes) ID of the command Hexadecimal parameters Little-endian mode Lower 8 bits of the sum of previous bytes

Figure 13 Command syntax of TF350

Source figure, page 22

OPTIONAL ACCESSORIES

6 OPTIONAL ACCESSORIES

NOTE The following accessories are not standard accessories, please contact our sales or technical personnel for more information.

6.1 Extension cord For testing purposes, we prepared an extension Dupont cord. See Figure 14 Extension cord for test for detailed information.

Source figure, page 22

Figure 14 Extension cord for test

NOTE This extension cord is free, but it’s not a standard accessory. Please contact us if needed.

Source figure, page 23

QUICK START GUIDE

7 QUICK START GUIDE

7.1 Connection and basic test

NOTE The product package contains only TF350 and factory certificate. If you need USB converter, please contact our sales or technical support.

 Download the latest version BW_TFDS from https://ai.benewake.com/zh/contact/#inquiry onto your PC or laptop.

Source figure, page 23

Figure 15 Benewake testing GUI for TF series

 See Figure 15 Benewake testing GUI for TF series of the GUI.  Connect TF350 to the PC or laptop with a paired USB converter cable as shown in Figure 16 TF350 connecting to PC. The UART version TF350 needs a UART-USB converter, and the CAN version TF350 needs a CAN-USB converter.

Source figure, page 23

Interface

converter

Figure 16 TF350 connecting to PC

Source figure, page 24

QUICK START GUIDE

 Run BW_TFDS.exe, choose the right baud rate and communication port, and click CONNECT to start the test.

7.2 Troubleshooting guide for initial test

In the default working mode, TF350 will automatically output data when connected to the PC following 7.1 Connection and basic test. If you cannot read data from GUI properly, follow these steps to locate and solve problems. S1. Check if there is red light inside TF350 through its window.

 No. Check power supply. If the power supply is normal, please contact Benewake service.  Yes. Proceed to S2. S2. Check whether the USB converter is paired with TF350. For example, TF350-100 CAN needs a USB-CAN converter.  No. Change a paired USB converter then try again.  Yes. Proceed to S3. S3. Check signal wiring. See Figure 7 Wiring of the UART interface and Figure 8 Wiring of the CAN interface for detailed wiring information.  Incorrect. Fix wiring.  Correct. Proceed to S4. S4. Some USB converters can generate more than one COM port. Try to connect through different COM port.  If all the COM ports don’t have data output, proceed to S5. S5. Send the command of reading firmware version, 5A 04 01 5F, through every COM ports. Try to read response.  If all the COM ports have no response, please contact Benewake service.  If one of the COM ports has correct response, send the command of restore default, 5A 04 10 6E, through this COM port. After sending this command, if the TF350 still doesn ’ t work, please contact Benewake service.

7.3 Working mode

TF350 has three different working modes.  Automatic output mode. This is the default working mode. The default frame rate of this mode is 10Hz.

Source figure, page 25

QUICK START GUIDE

 Command triggering mode. In this mode, TF350 will not output data automatically. TF350 output measuring data only when it receives the triggering command.  Low power consumption mode. In this mode, TF350 still output measuring data automatically. But the maximum frame rate has been restricted to 5Hz. Meanwhile its power consumption is reduced to 350mW.

NOTE Only the UART interface supports low power consumption mode.

7.4 Influences of object surfaces on the

measurement

The signal received from a perfectly diffuse reflecting white surface corresponds to the definition of a remission of 100%. As a result of this definition, the remissions for surfaces that reflect the light bundled (mirrored surfaces, reflectors), are more than 100%.

Source figure, page 25

Figure 17 Reflection of the laser beam at the surface of an object

The majority of surfaces reflect the laser beam diffusely in all directions. The reflection of the laser beam will vary as a function of the surface structure and color. Light surfaces reflect the laser beam better than dark surfaces and can be detected by the TF350 over larger distances. Brilliant white plaster reflects approx. 100% of the incident light, black foam rubber approx. 2.4%. On very rough surfaces, part of the energy is lost due to shading. The detecting range of the TF350 will be

Source figure, page 26

QUICK START GUIDE

reduced as a result.

Source figure, page 26

Figure 18 Reflection angle

The reflection angle is the same as the angle of incidence. If the laser beam is incident perpendicularly on a surface, the energy is optimally reflected (Figure 18 Reflection angle). If the beam is incident at an angle, a corresponding energy and detecting range loss is incurred.

Source figure, page 26

Figure 18 Degree of reflection

If the reflected energy returned is over 100% (basis: Kodak standard) the incident beam is not reflected diffusely in all directions, but is reflected in a specific direction. As a result, a large portion of the energy emitted can be received by the laser distance measurement device. Plastic reflectors (“cats’ eyes”), reflective tape and triple prisms have these properties.

Source figure, page 27

QUICK START GUIDE

Source figure, page 27

α

α

Figure 19 Mirror surfaces

At mirror surfaces the laser beam is almost entirely deflected (Figure 19 Mirror surfaces). Instead of the surface of the mirror, it is possible that the object on which the deflected laser beam is incident may be detected.

Figure 20 Object smaller than diameter of the laser beam

Objects that are smaller than the diameter of the laser beam cannot reflect all the energy of the laser light (Figure 20 Object smaller than diameter of the laser beam). The energy in the portion of the laser light that is not reflected is lost. This means that the detecting range is less than would be possible theoretically based on the surface of the object.

Source figure, page 28

QUICK START GUIDE

Dist = WightedAverage(D 1, D 2)

Figure 21 Staircase object

Staircase objects have two or more planes (Figure 21 Staircase object). The energy in the portion of the laser light that is reflected by different plane is different. TF350 will calculate a weighted averaging energy. The measured value will possible theoretically be the weighted average of distances from TF350 to different platform.

Source figure, page 29

TROUBLESHOOTING

8 TROUBLESHOOTING

NOTICE Claims under the warranty rendered void! The housing screws of the TF350 are sealed. Claims under the warranty against Benewake will be rendered void if the seals are damaged or the device opened. The housing is only allowed to be opened by authorized service personnel.

This chapter describes how to identify and rectify errors and malfunctions during the

operation of TF350. Table 9 Troubleshooting and rectification

ParameterValue
FailurePossible cause Solution
Measurement Optical signal was  Remove the obstacle or
exceeds the allowedblocked. adjust the detecting
error.direction.

 The target is a low  Paste a reflector on target reflectivity object. object.

ParameterValue
Measurements in the Protective film has not  Remove the protective
near range with nobeen removed. film.
measurement target. Contaminated or  Carefully clean optics using

scratched window. soft, fluff-free cloth.

If the optics are scratched, contact Benewake service.

 Rain or fog  Enable rain-fog filter

ParameterValue
TF350 is not Wiring fault in the data  Check wiring.
transmitting aconnection.
measured result. Wrong USB converter.  Check USB converter.
Data transmitted is Baud rate mismatch.  Check baud rate of the
garbage.receiving device.

Check TF350’s baud rate

setting.

A certain target  The target is too small.  Replace it with a larger cannot be detected target. Please refer to 2.5

Source figure, page 30

TROUBLESHOOTING

above.

 The target is a low  Sticking a high reflection reflectivity object. sticker on the surface of the

measured object.

Source figure, page 31

ATTACHMENT 1:REFLECTIVITY OF DIFFERENT MATERIALS

Attachment 1: Reflectivity of Different

Materials

The reflectivity of different materials is listed below, ranging from low to high. According to the test target and the corresponding reflectivity, we can measure whether the range of TF350 and other parameters meet the requirements.

No. Materials Reflectivity 1 black foam rubber 2.4% 2 black cloth 3% 3 black rubber 4% 4 Coal (varies from coal to coal) 4~8% 5 Black car paint 5% 6 Black paper 10% 7 opaque black plastic 14% 8 Clean rough board 20% 9 newspapers 55% 10 translucent plastic bottles 62% 11 packing case cardboard 68% 12 Clean pine 70% 13 opaque white plastic 87% 14 white card 90% 15 Kodak standard whiteboard 100% 16 Unpolished white metal surface 130% 17 Shiny light metal surface 150% 18 stainless steel 200% 19 Reflective board, reflective adhesive tape >300%

产品咨询

咨询产品方案

留下需求,我们会尽快与您联系。

产品咨询

提交成功

已收到您的询盘,我们会尽快与您联系。