跳到主要内容

技术资料

tf-uw500 技术资料

Benewake TF-UW500

Source figure, page 1

Benewake TF-UW500

Datasheet

TF-UW500 is a single-point LiDAR based on the Time of Flight (ToF) principle, utilizing a red laser light source. With its unique optical and electrical design, it achieves stable, precise, and highly sensitive underwater distance measurement. The product is equipped with multiple adaptive algorithms for various application environments and targets, and it offers a lot of adjustable configurations and parameters. It is particularly suitable for various applications on pool cleaning robots used outdoors under strong sunlight.

Technical Specifications

Performance Parameters

ParameterValue
ModelTF-UW500
Detection range under> Indoor, NTU< 0.5, 30% reflectivity, the light beam is perpendicular to 5 m
waterthe target surface
Blind zone≤ 0.1 m
Accuracy ①< 3 cm ( 0.1 ~ 2m )
Repeatability ①< 1 cm @ 1 σ ( 0.1 ~ 2m )
Distance resolution1 mm
Default frame rateDefault 20 Hz
Ambient light resistance100 KLux

Optical Parameters

ParameterValue
Light sourceLaser
Central wavelengthRed
FoV< 0.5°
Eye safetyClass1 (IEC 60825-1:2014; EN 60825-1:2014+A11:2021)

Mechanical and Electrical Parameters

ParameterValue
Average power consumption ②< 5V × 100mA
Peak current at start up ②< 700mA
Power supplyDC 5 ± 0.2 V
Logical voltage3.3 V TTL
Connector1.0mm-4P, model is HC-1.0-4PWT
Operating temperature0 ℃ ~ + 50 ℃
Storage temperature- 20 ℃ ~ +70 ℃
Protection levelNA
Typ. Dimensions ③24.0 mm × 16.0 mm × 20.4 mm
Typ. Weight ③< 5 g (excluding cables)

Communication Protocol

ParameterValue
Communication InterfaceUART / I ² C (Can be switched by command)
Baud rateDefault 115200 (Configurable)
Data bit8
Stop bit1
ParityNone

Dimensions (Unit: mm)

Source figure, page 2
Source figure, page 2

Notes:

1. 100 KLux , NTU < 0.5 , 30% reflectivity (Common materials such as white tiles, blue and white tiles, marble, cement, etc), vertical incidence, water depth greater than 1m;

2. Measured indoors at 0 Klux, 25 ℃, for reference only, parameters may change due to environmental changes;

3. The weight and size are typical values for reference only. For detailed tolerance parameters, please consult the technical personnel of Benewake.